Pxie-4162. Try searching for what you need. Pxie-4162

 
 Try searching for what you needPxie-4162  The AC power cord grounds the chassis and protects it from electrical damage while you install the PXIe-4163

PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Existing code created with earlier versions of NI‑DCPower and that contains Express VIs will continue to execute, but the Express VI cannot be reconfigured from a dialog box. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Supported Hardware. This arbitrary waveform generator can generate signals from -12 V to +12 V and uses a fractional. 机箱中的PXI(e)板卡无法在NI MAX中执行自校准以及收到以下错误信息: Status Code: -201295 Device could not complete the calibration operation. Read this document and the documents listed in the additional resources section about. a 62 D-sub male to bare wire male low-leakage cable intended for use with PXIe-4162/4163 Source Measure Units. The SHDB62M-DB62M-LL is optimized for low-leakage and low-thermal electromagnetic fields (EMF) and reduces current leakage when supplying power to the PXIe-4162 and PXIe-4163 PXI Source Measure Units (SMUs). OCP is triggered when a fault condition occurs that would otherwise cause the device to sink or source current beyond its specifications for an excessive amount of time. GETTING STARTED GUIDE PXIe-4147 PXIe, 4-channel ±8 V, 3 A PXI Source Measure Unit This document explains how to install, configure, and test the PXIe-4147. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Wait two minutes for thermal EMF to stabilize. 这减少了类似其他 SMU 在力和感测之间的自动感测电阻器引起的误差. NETクラスライブラリを使用している場合、. At initialize and reset, several routines are run on the hardware, but I don't think they might be slowly degrading the instrument. National Instruments PXIe-4141 Source Measure Unit (SMU) This item is sealed in the manufacturer's static bag. NET Framework 4. For the PXIe-4141, PXIe-4143, and the PXIe-4145, adding a small resistance in series with each channel can be substituted by instead programming each channel with a small amount of output resistance (0. ALL RIGHTS RESERVED. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. NI-DCPower is an interchangeable virtual instrument (IVI)–compliant instrument driver, and it features a set of operations and properties that exercise the functionality of the power supply or SMU and includes an. NI-DCPower is an NI instrument driver that communicates with all NI programmable power supplies and SMUs. Microsoft Visual Studioのサポート. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Once you have found. 6. 0 (最低限) が必要です。PXIe-4145 PXIe-4162 PXIe-4163 드라이버. National Instruments PXIe-4162 Source Measure Unit (SMU)Configuration: Number of SMU Channels: 12 Voltage Range: -24 V to 24 V Current Range: -100 mA to 100 mA Current Sesitivity: 100 pA Source Adapt: Yes Part Number: 785680-01Please contact Artisan Technology Group Sales for configuration pricingPXIe-4162: 786984-01: SHDB62M-DB62M-LL SHDB62M-BW-LL: n/a: PXIe-4163: 786985-01: SHDB62M-DB62M-LL SHDB62M-BW-LL: n/a *Triaxial cables are compatible with the PXIe-4138/4139 if using the SA-413T adapter. For example, the Active Load current range for the PXIe-6570 is 1. NI-VISA. Caution Do not exceed the operating specifications for the module connected to the SHDB62M-BW-LL. D-subminiature connectors are named for the D-shaped shroud present at their mating end and the relatively high interconnect density offered at the time of their introduction. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Disconnect or disable all connections to the PXIe-4162/4163. single-family home is a 4 bed, 3. PXIe-4163 Purpose and Introduction. Measurement Aperture, Nominal 555. Options. Call the self-calibration function. It has an activity of 4 quadrants with a current resolution of 100 pA and the ability to test up to 100 kS/s. PXIe-4162 / 785680-01 - NI. PXIe-4163 DC Current Source and Sink Ranges, Warranted Chassis Slot Cooling Capacity ≥58 W 38 W 10 μA 100 μA 1 mA 10 mA 50 mA 30 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). 8 PXIe-4162 configured for fast transient response. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. This cable is designed for use with SMUs (Source Measure Units) such as the PXIe-4162 and PXIe-4163. 6 Supported Hardware The following hardware models are supported in InstrumentStudio 2018 SP2:The SHDB62M-DB62M-LL is optimized for low-leakage and low-thermal electromagnetic fields (EMF) and reduces current leakage when supplying power to the PXIe-4162 and PXIe-4163 PXI Source Measure Units (SMUs). The Overcurrent Protection (OCP) has been activated. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. ground through the shell of the PXIe-4162/4163 front panel connector. Return to Home Page; Toggle navigation; Solutions. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Industries. 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). It also features. NI‑DCPower 19. This file contains important information about InstrumentStudio 2021 Q4, including supported hardware and operating systems, a partial list of bugs fixed, and known issues. 8 ms/s isolated digitizer, l and c measurement support, pxi. 1. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. NI‑DCPower 19. This is not an exhaustive list of issues fixed in the current version of NI-DCPower. Installing the TB-4162. Please refer NI's whitepaper on merging SMU channels. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. PXIe-4162 SMU drivers GastonBA. NI-DCPower 21. 3. Industries. 60 lb) typical PXIe-8842 753 g (1. This cable is insulated by an outer layer of Teflon. Manuals. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. 6. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。 From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The NI SHDB62M-DB62M-LL comes with a shielded, 62-Pin D-Sub male front end connector and an identical back end connector. 5 bath, 1614 sqft single family home located at 4162 Tuxedo Dr built in 1995 on Zillow. A red blinking light will generally indicate that the power supply to the chassis is out of spec. It features 4-quadrant operation, and each channel has integrated. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. Existing code created with earlier versions of NI‑DCPower and that contains Express VIs will continue to execute, but the Express VI. 5. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. NI-DAQmx. Do not exceed the isolation voltage of the instrument. It helps simplify the task of designing automated test systems for a wide range of applications—from aerospace. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. 8. Technical Documents (1) Technical Data Sheet EN 0 In stock. NI. I am opening a ticket. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. You can also use InstrumentStudio to monitor and control devices being used in external applications, capture data files, export device configuration to other applications, and more. It sounds like you can open a session to a device and use it periodically and after some amount of time the session is invalidated. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 pA or high. Re: PXIe-4163 running voltage sequence occur "Internal Hardware Error". The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Use the self-calibration function to reduce errors caused by time and temperature drift. Figure 2. Contact us with questions for pricing. Complete the following steps to self-calibrate the PXIe-4162/4163. When attempting to self-test my PXIe-4163 SMU from NI MAX, I see the following error: The self test failed. measurements, as well as analog-to. 5. Pxie, 12-channel, 24 v, 100 ma pxi source measure unit (20 pages) Measuring Instruments National Instruments PXIe-4162 Manual (19 pages) Measuring Instruments National Instruments NI PXIe-4139 Calibration Procedure. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. 4 V peak, or 60 VDC. NET Class Library, the . 5Ω-1Ω is adequate for this method as well), as shown in Figure 6. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. procedures for the PXIe-4162/4163. The following diagram shows a cross-section of the SHDB62M-DB62M-LL when used with a PXIe-4162. Part Number: 782430-01. PXIe-4162 (785680-01) PXI Express: 12: 2. Caution Limit DC power sinking to 12 W. 2. The SHDB62M-DB62M-LL is a Low Leakage Cable from National Instruments. Use the procedures in this document to automate calibration or to conduct manual calibration. Email: info@artisantg. 2 W-24 V to 24 V:Ambient temperature ranges of 0 °C to 45 °C The PXIe-5162 is warmed up for 15 minutes at ambient temperature Self-calibration is completed after warm-up period Calibration cycle is maintained The PXI Express chassis fan speed is set to HIGH, the foam fan filters are removed if present, and the empty slots contain PXI chassis slot blockers andPXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. Contact Us for Immediate Support or Read More. 5 n olts) 100 n 1 μ 10 μ 100 μ 1 m 10 m 100 m 1 μ 10 μ 100 μ Aperture (Seconds)PXIe-4147. Due to market conditions delivery times are for general guidance only and may be subject to. 8. 2 For increased capability, NI recommends installing the PXIe-4147 in a chassis with slot cooling capacity ≥58 W. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. For the purpose of this issue, we only care about the computer in which the PXIe-4162 is. NI-488. 6 adds support for the PXIe-4162 and PXIe-4163 source measure units. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. Return to Home Page; Toggle navigation; Solutions. The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. Buy Source Measurement Units - SMUs. For voltage >60 V DC and triaxial connectivity, consider the PXIe-4135 SMU with native triaxial connectors. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. 0 (minimum) is required. Together, the two modules create a reconfigurable instrument that you can program with. The module also offers the capacity to amplify steadiness and estimation exactness with the. Resistance Specifications Accuracy All resistance accuracy specifications apply to apertures of ≥100 ms, with Offset Compensated Ohms (for ranges ≤10 kΩ) or Auto Zero (for ranges ≥ 100 kΩ) and ADC calibration enabled. Environmental. Pxie-4163 Pinout and Leds. 0 (minimum) is required. Typically, I would initialize my hardware once. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. Caution Using the NI PXIe-7820R in a manner not described in this document may impair the protection the. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. Looking for something else? For information not found in the User Manual for your product, like specifications or API reference, browse Related Information. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. This is not an exhaustive list of issues fixed in the current version of NI-DCPower. The PXIe-4137 is a high-precision, system source measure unit (SMU). You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. Provides precise voltage or current sourcing and measurement capabilities for PXI systems. A valid service agreement may be required. Industries. 0 dropped support for Express VIs in LabVIEW. Phone: (217) 352-9330. Voltage Output and Measurement Connecting and Configuring Equipment for Voltage Verification 1. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. This is not an exhaustive list of issues fixed in the current version of NI-DCPower. Microsoft Visual Studioのサポート. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. 次の表および図は、PXIe-4162の電圧および電流ソースとシンクのレンジを示します。 表 1. Specifications Note In this document, the PXIe-4162 (10 pA) and PXIe-4162 (100 pA) are referred to inclusively as the PXIe-4162 . You use the PXIe‑8862 for processor-intensive RF, modular instrumentation, and data acquisition applications. 8 MS/s Isolated Digitizer, L and C Measurement Support, PXI Digital Multimeter. The rugged, all-metal PXie printers deliver outstanding performance – up pxie-4112は、2つの出力チャンネルを持つ単一象限電源です。両方の出力チャンネル で同じ出力を出すことができます。チャンネルはチャンネル間およびシャーシグラン ド間で絶縁されています。 dc電圧 電圧レンジ 60 v プログラミング可能な最小電圧レベ ル. This document explains how to install, configure, and test the PXIe-4162. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. the PXIe-4162. Caution Do not exceed the operating specifications for the module connected to the SHDB62M-BW-LL. 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). 62 MB Table of Contents. Return to Home Page; Toggle navigation; Solutions. PXIe-4162 DC Current Source and Sink Ranges, Warranted Chassis Slot Cooling Capacity ≥58 W 38 W 10 μA 100 μA 1 mA 10 mA 100 mA 60 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). 0 dropped support for Express VIs in LabVIEW. TB-4162 Specifications These specifications apply to the TB-4162 terminal block for use with the PXIe-4162. But if I try to draw a lower negative current. •Source Adapt: Yes. . used. Solution. com. NIが設計するシャーシはこうした要件を上回っており、各スロット. This is not an exhaustive list of issues fixed in the. You can also use InstrumentStudio to monitor and control devices being used in external. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog. Microsoft Visual Studioのサポート. If you have an issue ID, you can search this list to validate that the issue has been fixed. Remote sense can be enabled or disabled using the niDCPower Configure Sense VI on a per output basis for channels that support this feature. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. 62-Pin D-SUB Male to 62-Pin D-SUB Male, 60 VDC, 100 mA, Braided Low-Leakage Cable for SMU—The SHDB62M-DB62M-LL is optimized for low-leakage and low-thermal electromagnetic fields (EMF) and reduces current leakage when supplying power to the PXIe-4162 and PXIe-4163 PXI Source Measure Units (SMUs). •Voltage Range: -200 V to 200 V. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. NI-DCPower is an interchangeable virtual instrument (IVI)–compliant instrument driver, and it features a set of operations and properties that exercise the functionality of the power supply or SMU and includes an. NI-DCPower is an interchangeable virtual instrument (IVI)–compliant instrument driver, and it features a set of operations and properties that exercise the functionality of the power supply or SMU and includes examples. •Source Adapt: Yes. I am interested in using Remote Sense to verify I am supplying the right voltage output. 8 MS/s. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. Industries. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. This page documents all the applicable standards and certifications for the ACC-4162-1 and provides downloadable certifications. 0: The NI-DCPower Soft Front Panel has been replaced by InstrumentStudio, which is automatically installed when you install the NI‑DCPower driver. Brand: National Instruments | Category: Recording Equipment | Size: 0. Find the cable or accessory model name below to see its description. PXIe-4162 DC Current Source and Sink Ranges, Warranted Chassis Slot Cooling Capacity ≥58 W 38 W 10 μA 100 μA 1 mA 10 mA 100 mA 60 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). Verifying the System RequirementsPXIe-4112. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. I am opening a ticket. Only combine channels of the same instrument. SPECIFICATIONS PXIe-4162 PXIe, 12-Channel, ±24 V, 100 mA Precision PXI Source Measure Unit Definitions Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. 0 has the following requirements: Processor—2. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. 2. Related information: PXIe-4162 Specifications 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。 The PXIe-4162 (Part Number: 785680-01) is a unit of estimation of high-density source (SMU)-the device is equipped with 12 SMU channels. 2 For increased capability, NI recommends installing the PXIe-4162 in a. This document explains how to install, configure, and test the PXIe-4162. Caution Shock hazards exist when voltage levels are greater than 30 VRMS, 42. The PXIe-5162 high-speed oscilloscope device has two or four channels that sample at up to 5 GS/s with flexible settings for coupling, voltage range, and filtering. 8 MS/s 100 kS/s Max Update 100 kS/s Max Voltage 10 V 24 V 6 V 8 V 24 V 24 V Max DC Current 100 mA 150 mA 500 mA 3 A 100 mA 50 mA Current Sensitivity 100pA/10pA 100pA/10pA 150pA/15pA 100 fA 10pA/100pA. Screw Terminal Connector Kit for PXIe-4162 SMU (NI part number 786984-01) Output regulation provided by a high-impedance connection between force and sense lines for scenarios where the sense lines disconnect from the DUT. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisFind new, used, and rental NI PXIe-4162 PXIe-4162 12-Channel Precision SMU, 24V 785680-01 at Electro RentMeasuring Instruments National Instruments PXIe-4162 Manual (19 pages) Measuring Instruments National Instruments PXIe-4080 Calibration Procedure. 1 Maximum 480 mA per module. Return to Home Page; Toggle navigation; Solutions. PXIe-4143 National Instruments PXIe-4143 Source Measure Unit (SMU) from National Instruments | Buy Today from Artisan. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. National Instruments PXI-8331 User Manual (43 pages) MXI-4 Series Multi-System Extension Interface for PCI, CompactPCI, and PXI Bus Computers. This document explains how to install, configure, and test the PXIe-4162. Please contact Artisan Technology Group Sales for configuration pricing and availability. dubatov. However, the connections will be made as seen in Figure 2. The 1,809 Square Feet single family home is a 3 beds, 2. The PXIe-4162 is a 12-Channel, ±24 V, 100 mA source measure unit (SMU). PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXIe-4162; PXIe-4163; PXIe-4190; Behavior Changes. PXIe-4144 PXIe-4145 PXIe-4162 PXIe-4163 问题详述 我想并行连接多个SMU通道,所以我可以增加可用电流量。是否建议将源测量单元并联? 解决方案. •Current Sesitivity: 100 pA. source measure unit (SMU) and includes TB-4162 specifications. Added support for multichannel session in the SMU/Power Supply panel, newly supported in NI-DCPower 20. Brand: National Instruments | Category: Touch terminals | Size: 0. com. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit. 0: The NI-DCPower Soft Front Panel has been replaced by InstrumentStudio, which is automatically installed when you install the NI‑DCPower driver. It seems really easy but I cannot figure out. PXIe, 24-Channel, ±24 V, Precision PXI Source Measure Unit. •Current Range: -150 mA to 150 mA. The DUT is charged to a voltage that does not match the SMU. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. Initialize an NI-DCPower session containing all device channels. Table 1. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. Adding the. Return to Home Page; Toggle navigation; Solutions. PXI-4110; PXIe-4112; PXIe-4113; PXIe-4154; PXI-4130; PXI-4132; PXIe-4135; PXIe-4136; PXIe-4137;. Electro Rent Remains Ready and Available to Support Customers Through COVID-19 Challenges. You can. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. The module may be installed into any PXI Express-compatible slot. pxie-4162是一款高精度、高密度源测量单元(smu),具有12个相同的smu通道。该模块支持四象限运行,每个通道集成远程(4线)感应功能以实现准确测量,并且运用模数转换器技术,帮助您执行高精度测量。Solution. PXIe-4162; PXIe-4163; LabVIEW NXG Help. Complies with the essential requirements of the following applicable UK Regulations: Electromagnetic Compatibility (EMC) Regulations 2016 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic. 10 20 Hz to 20 MHz bandwidth. PXIe-5160/5162 Signal Descriptions Signal Connector Type Description CH 0, CH 1 BNC This page provides dimensional drawings for the PXIe-4162. Please contact Artisan Technology Group Sales for configuration pricing and availability. Industries. 3 No support for PXIe-4162/4163 source measure units. In addition, numerous NI-DCPower properties can now be configured per channel rather than per session. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisNI PXIe-4162/4163 Source Measure Units Product Range: SHDB62M-BW-LL Find similar products Choose and modify the attributes above to find similar products. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 pA or high. Touch any metal part of the chassis to discharge static electricity. If I set the PXIe-4162 to draw a higher negative current, say -150 uA, I can measure the current to be exactly -150 uA. You will need to ensure that the value set for current limit is within the current limit. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. You can request. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure UnitPXIe-4162 / 785680-01 - NI. The following items are notable issues fixed between the release of NI-DCPower 2022 Q3 and NI-DCPower 2022 Q4, including additional patches and service packs. NI-DCPower 21. Table 1. Industries. 6: To support independent channels, numerous NI-DCPower functions have been superseded by new versions that can access instrument channels independently. Calibration could fail for the following reasons: 1. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. A valid service agreement may be required. The fast sample rate of the PXIe-4141 can reduce measurement times. Measurement Aperture, Nominal 555. It also features. Each * 1+ $797. 2D Dimensional Drawings. See all Driver Software Downloads. 5 GHz, 5 GS/s, 10-Bit PXI Oscilloscope. 0: The NI-DCPower Soft Front Panel has been replaced by InstrumentStudio, which is automatically installed when you install the NI‑DCPower driver. Close the NI. 5 digits. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。Model Number(s): PXIe-4162 Product Category: Electrical equipment for measurement, control, and laboratory use. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 pA or high-speed acquisitions up to 100 kS/s per. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. Min: 1 Mult: 1. 2. NI-DCPowerは、NIのすべてのプログラマブル電源とSMUと通信するための計測器ドライバです。NI-DCPowerは、IVI (Interchangeable Virtual Instrument) に準拠した計測器ドライバで、電源供給またはSMUの機能を実行する操作とプロパティのセットを提供します。ni. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. 5 has the following requirements: Processor—2. The only other things plugged into the board were SMU's and PXI-6570, all in the same chassis. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. NI SMUs have a hardware-timed, deterministic sequencing engine that allows the instrument to execute commands and acquire data without any intervention from the host software. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. 5 digits. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Before you begin, install and configure your chassis and controller. A valid service agreement may be required. PXIe-4162 Quadrant Diagram, Any Channel 60 20 40 0 100 80 ±100 ±24 ±20 ±15 ±10 ±5 0 5 10 15 20 24 ±40 ±60 ±80 ±20 Current (mA) Voltage (V) 2 mA/V 2 mA/V Quadrant II Quadrant III Quadrant IV Quadrant I Valid on any channel in a PXIe-1095 chassis. Additional derating applies to sinking power when operating at an ambient temperature of >45 °C. 如何为我的 SMU 配置电流限制? niDCPower Configure Current Limit Range VI 和 niDCPower Configure Current Limit VI 有什么区别?. This is not an exhaustive list of issues fixed in the current version of NI-DCPower. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 pA or high. These rugged printers deliver advanced connectivity and network protocols, ensuring peace of mind today and a reliable, scalable solution for the long haul. No more than 2 channels combined (usually there’s a better alternative > 2 channels). It may be true, but I don't have enough evidence to back up that claim. Indoor use only. The PXIe-4163 ships with NI-DCPower driver software, which you can use to program the module. Return to Home Page; Toggle navigation; Solutions. Terminal Block, TB-4353, PXIe-4353 PXI Temperature Input Module. 4162 Roy Pl, Victoria, BC V8Z 7X3 is currently not for sale. •Voltage Range: -24 V to 24 V. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. NI GPIBコントローラおよびGPIBポートを備えたNI組込コントローラをサポートします。. The PXIe-5423 is a 40 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms and standard functions including sine, square, triangle, and ramp. Initialize with channel -> configure -> initialize -> measure -> close. Looking for something else? For. Return to Home Page; Toggle navigation; Solutions. The following items are notable issues fixed between the release of NI-DCPower 2022 Q3 and NI-DCPower 2022 Q4, including additional patches and service packs. Complies with the essential requirements of the following applicable UK Regulations: Electromagnetic Compatibility (EMC) Regulations 2016 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic. Operating Environment. NI-DCPowerは、NIのすべてのプログラマブル電源とSMUと通信するための計測器ドライバです。NI-DCPowerは、IVI (Interchangeable Virtual Instrument) に準拠した計測器ドライバで、電源供給またはSMUの機能を実行する操作とプロパティのセットを提供します。PXIe, 6 1/2-Digit, +/-300 V, Onboard 1. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。. Overview. 2 | ni. Important Notice: Other accessories, manuals, cables, calibration. The TB-4162 terminal block is used for screw terminal connections with the PXIe-4162 SMU. If you have an issue ID, you can search this list to validate that the issue has been fixed. This document explains how to install, configure, and test the PXIe-4163. National Instruments PXI-8331 User Manual (43 pages) MXI-4 Series Multi-System Extension Interface for PCI, CompactPCI, and PXI Bus Computers. NI‑DCPower 19. Table 1. The PXIe-4162/4163 SMU differ from other SMUs in architecture. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Back to top. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Higher power. PXIe-4163. NI-DCPower 17. You can request repair, RMA, schedule calibration, or get technical support. Power down the computer, then the PXI (e) chassis. 2 Channels are isolated from earth ground but share a. PXIe, 12-Channel, ±24 V, 100 mA PXI Source Measure Unit. 5. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisThe following items are notable issues fixed between the release of NI-DCPower 2022 Q3 and NI-DCPower 2022 Q4, including additional patches and service packs. 8 MS/s. Table 1. Ensure that the reference signal applied is the. Windows Embedded Standard 7 (SP1) Windows Server 2008 R2 (SP1) 64-bit. The SHDB62M-DB62M-LL is optimized for low-leakage and low-thermal electromagnetic fields (EMF) and reduces current leakage when supplying power to the PXIe-4162 and PXIe-4163 PXI Source Measure Units (SMUs). Related Links. The PXIe-4147 ships with NI-DCPower driver software, which you can use to program the module. Return to Home Page; Toggle navigation; Solutions. You can access the software and documentation known issues list online. The force voltage will reach 25V but other NI SMUs will not show this problem. PXIe-4162/4163 12 or 24-Channel, ±24 V Precision PXI Source Measure Unit This document contains the verification and adjustment procedures for the PXIe-4162/4163. You can also view context help for the search results. The PXIe-4162/4163 SMU differ from other SMUs in architecture. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. 1: NI 411x, 413x, 414x, and 4154 Power Supplies and SMUs. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisPXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisPXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisNational Instruments PXIe-4135 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 1. 2 For increased capability, NI recommends installing the PXIe-4147 in a chassis with slot cooling capacity ≥58 W. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。 PXIe-5162 1 MΩ Frequency Response, 1 Vpk-pk, Measured17 1 –19 –17 –15 –13 –11 –9 –7 –5 –3 –1 Frequency (Hz) 50 k 100 M 200 M 300 M 400 M 500 M 600 M 700 M 800 M ed Amplitude (dB) Figure 6. PXIe-4144; PXIe-4145; NI 416x SMUs. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. 2. With a national network of resources, a robust quality program and broad capabilities, we offer standard and custom solutions to deliver fast, accurate calibration when and how it's needed. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. 10-20-2022 02:07 PM. 2 For increased capability, NI recommends installing the PXIe-4163 in a chassis with slot cooling. 4 W: 1. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. This document explains how to install and use the TB-4162 terminal block with a PXIe-4162. You can request repair, RMA, schedule calibration, or get technical support. The PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. This home was built in 2003 and last sold on. Search for items using the search bar in the upper right corner of the LabVIEW window.